Seitenansicht 6
An internal relay may be used to
enable external ampli ers when the
controller has powered up correctly
and the system and application
software are ready. The ampli er
enable is a single pole solid state
relay with a normally open “contact”.
The enable relay contact will be open
circuit if there is no power on the
controller OR an axis error exists OR
the user program sets it open with
the WDOG=OFF command.
EtherCAT drives will be enabled via the EtherCAT network so the
“Ampli er Enable” connection is not normally required.
All non EtherCAT stepper and servo ampli ers MUST be inhibited
when the ampli er enable output is open circuit
An additional safety relay may be required so as to meet
machine safety approvals.
AMPLIFIER ENABLE
(WATCHDOG)
RELAY OUTPUT
Ampli er
Enable 1
Ampli er
Enable 2
To other axis enables
24V 0V
0V
Enable
CONTROLLER SERVO AMPLIFIER
Enable
Input 0
Input 1
Input 2
Input 3
Input 4
Input 5
Input 6