(Please refer to the Motion Coordinator Technical Reference Manual for Full Details)
MOTION COORDINATOR
MC403 / MC403-Z
Quick Connection Guide
M
O
T
I
O
N
C
O
O
R
D
I
N
A
T
O
R
MICRO SD CARD
CAN PORT FOR TRIO CAN
I/O, DEVICENET SLAVE,
CANOPEN OR USER
PROGRAMMABLE
RS232 / RS 485
MODBUS-RTU,
HOSTLINK OR USER
PROGRAMMABLE
ETHERNET
PROGRAMMING, MODBUS-
TCP, ETHERNET IP
8 DIGITAL INPUTS
INCLUDING
6 X REGISTRATION INPUTS
AND 4 BI-DIRECTIONAL I/O
STATUS LEDS
3 ENCODER CONNECTIONS
(6MHZ) OR DRIVE AS
STEPPER OUTPUTS
(2MHZ)
PANEL MOUNT OR DIN
RAIL MOUNT
2 ANALOGUE INPUTS AND
2 VOLTAGE OUTPUT AND
WDOG RELAY
Seitenansicht 0
1 2 3 4 5 6 7 8

Inhaltsverzeichnis

Seite 1 - MICRO SD CARD

(Please refer to the Motion Coordinator Technical Reference Manual for Full Details)MOTION COORDINATOR MC403 / MC403-ZQuick Connection GuideMOTIONCOOR

Seite 2 - CONNECTOR

MC 403This is a 5 way 3.5mm pitch connector. The connector is used both to provide the 24 Volt power to the MC403(-Z) and provide connections for I/O

Seite 3 - 24V Power / Inputs / I/O

SERIAL CONNECTIONSMC 403MC 403Serial ConnectorI/O CONNECTOR 1Input 6Input 5Input 7I/O 8I/O 9I/O 10I/O 11Input 3Input 4Input 2Input 1Input 0I/O 24VI/O

Seite 4 - Output impedance: 100 Ohms

Aout0V100R100nF0VD to ACONVERTERAin0V22k22k30pFA to DCONVERTER0VI/O 24V must be applied to power the voltage outputs. (MC403 ONLY)or N/C = MC403-Zor N

Seite 5 - RELAY OUTPUT

An internal relay is used to enable external amplifi ers when the controller has powered up correctly and the system and application software are ready

Seite 6 - STEPPER

MC 403STEPPER OUTPUTS / ENCODER INPUTS* Current limit is 150mA total, shared between all axes.Pin Servo Axis Stepper Axis Absolute Encoder1 Enc. A St

Seite 7 - SHIELDING

Ensure that:1. The shield screw is grounded as close to the MC403(-Z) as possible.2. 0V, V- and E- connections are NOT used for terminating screens.3

Seite 8 - Website: www.triomotion.com

STATUS LED’SThe factory default IP address is 192.168.0.250. This can be changed using the ETHERNET or IP_ADDRESS commands via Motion Perfect. To retu